5-13.Component Pb Signal Timing
Adjustment
BOARD
V IN (F5)
TP
Component Pb OUT
ADJ.
Service Menu
TAPE
-----
INPUT
Analog Component Signal (Bowtie)
bCAM Level
MODE
EE
M. EQ
Analog WFM (Bowtie mode)
SPEC.
Relative Timing: 0 ± 5nsec
1.
Open the SERVICE MENU. (Refer to SEC1
Service Information.)
2.
Select the E00: V IN ADJUST and press the
"SET" button to open the V IN ADJUST MENU.
Select E-1 CMPNT ADJUST and press the "SET"
3.
button to open the CMPNT ADJUST menu.
Adjust the E04 NENT PB TMG so that the
4.
crossing point of the Bowtie signal becomes a
center (Timing =
0 ± 5nsec
5.
Close the menu.
).
ELE-25
5-14.Component Pr Signal Timing
Adjustment
BOARD
V IN (F5)
TP
Component Pr OUT
ADJ.
Service Menu
TAPE
-----
INPUT
Analog Component Signal (Bowtie)
bCAM Level
MODE
EE
M. EQ
Analog WFM (Bowtie mode)
SPEC.
Relative Timing: 0 ± 5nsec
1.
Open the SERVICE MENU. (Refer to SEC1
Service Information.)
2.
Select the E00: V IN ADJUST and press the
"SET" button to open the V IN ADJUST MENU.
Select E-1 CMPNT ADJUST and press the "SET"
3.
button to open the CMPNT ADJUST menu.
Adjust the E07 NENT PR TMG so that the
4.
crossing point of the Bowtie signal becomes a
center (Timing =
0 ± 5nsec
5.
Close the menu.
).