8 OTHER FUNCTIONS

8.1 X-over bonding

When the X-over detection function is enabled, the nozzle clearance can be changed automatically at places where the
thickness of the lower cloth changes greatly.
If the X-over detection function is enabled when using thin lower cloth, changes in the thickness of the lower cloth may
not be detected, and the nozzle clearance may not change.
In such cases, disable the X-over detection function, and follow the procedure given in "Switching the program while
gluing".
Refer to "Switching the program while gluing" in "6.2 Gluing" for details on the method of use.
If the setting for the nozzle clearance in the selected program is very narrow, the nozzle clearance may change at places
where the thickness of the lower cloth does not change.
In such cases, make the setting for memory switch No. 422 smaller.
Refer to "3.5" for details on the memory switch setting method.
*
Set memory switch No. 421 to "ON".
1.
2.
If you would like to change the amount by which the nozzle clearance changes, change the setting for memory switch No.
424.
*
When "AUTO" is set, the amount of change in the nozzle clearance will be the same as the setting value for the
nozzle clearance in the currently-selected program.
At the time of shipment from the factory, it is set to "AUTO".
*