9 REPLACING GLUE CARTRIDGE
Turn the melter cover (1) in the direction of the arrow to remove it.
3.
(1)
NOTE:
he metal part (A) inside the removed melter cover (1), the glue cartridge (2), the cartridge valve (3) and the melter (4) will all be
hot, so be careful not to touch them directly against your skin. If they touch your skin, burns may result.
lace the removed melter cover (1) onto the table. Do not place the melter cover (5) onto the bonding machine, as it may fall off.
Take off the glue cartridge (2).
4.
With the cartridge valve (3) facing upward, use a wrench to remove the cartridge valve (3) from the glue cartridge (2).
5.
NOTE:
Set the cartridge valve (3) so that it is facing upward before removing it, and be careful not to get any of the glue into your eyes
or onto your skin. If the valve is facing downward, glue may flow out and problems such as burns, inflammation or allergic
reactions could result.
Follow all applicable regulations when disposing of used glue cartridges.
58
(1)
(2)
(3)
(4)
BM-2000