Environmental Condition - Epson Stylus PHOTO 2000P Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus PHOTO 2000P:
Table of Contents

Advertisement

EPSON Stylus PHOTO 2000P
Dielectric strength:
AC 1000 V rms. 1 minute or
220-240 V version
Rated voltage:
AC 220 - 240 V
Input voltage range:
AC 198 - 264 V
Rated frequency range: 50 - 60 Hz
Input frequency range: 49.5 - 60.5 Hz
Rated current:
0.2A
Power consumption:
Approx. 1815W (ISO10561 Letter Pattern)
Approx. 3.5W in standby mode
Energy Star compliant
Insulation Resistance: 10 M ohms min.
(between AC line and chassis, DC 500 V)
Dielectric strength:
AC 1500 V rms. 1 minute
(between AC line and chassis)
Product Descriptions
AC 1200 V rms. 1 second
(between AC line and chassis)
Printing specification

1.2.5 Environmental condition

Temperature
: 10 to 35
C (operating *3)
°
: -20 to 60
C (non-operating, *1)
°
1 month at 40
120 hours at 60
Humidity
: 20 to 80% RH (operating, *2,*3)
: 5 to 85% RH (non-operating, *1, *2)
Resistance to shock: 1 G, within 1 ms (operating)
: 2 G, within 2 ms (non-operating, *1)
Resistance to vibration: 0.15G (operating)
: 0.50G (non-operating, *1)
NOTE: *1: with shipment container
*2: without condensation
*3: Condition is as following figure.
90
80
70
60
Humidity (%)
50
40
30
20
Figure 1-1. Environmental Condition
Revision A
C
°
C
°
27 30
35
40
10
20
Temperature (°C)
13