3
3.2.3

Automatic Rebuild and Manual Rebuild

Automatic Rebuild
One member drive
fails in logical drive
When a member drive in the logical drive failed, the controller will
first check whether there is a Local Spare Drive assigned to this
logical drive. If yes, it will automatically start to rebuild.
If there is no Local Spare Drive available, the controller will search
for a Global Spare Drive. If there is a Global Spare Drive, it will
automatically rebuild the logical drive.
If neither a Local Spare Drive nor a Global Spare Drive is available,
and the "Periodic Auto-Detect Failure Drive Swap Check Time" is
"Disabled," the controller will not try to rebuild unless the user
applies a forced manual rebuild.
When the "Periodic Auto-Detect Failure Drive Swap Check Time" is
enabled (i.e., a check time interval has been selected), the controller
will detect whether or not the failed drive has been swapped (by
checking the failed drive's channel/ID). Once the failed drive has
been swapped, the rebuild will begin immediately.
If the failed drive is not swapped but a local spare drive is added to
the logical drive, rebuilding will begin with the spare drive.
20
Waiting for spare
No
drive to be added
or manual rebuild
ASUS PCI-DA2100/PCI-DA2200 User's Manual
Any
local spare drive
assigned to logical
drive?
No
Any
global spare drive
assigned to logical
drive?
No
"Periodic
Auto-Detect Failure
Drive Swap Check Time"
enabled?
Yes
Has the
failed drive been
swapped?
No
Keep detecting if drive
has been swapped or
spare drive has been
added
Rebuild using the
Yes
local spare drive
Yes
Rebuild using the
global spare drive
Yes
Rebuild using the
swapped drive

Advertisement