(2) Connection of disk array unit with host unit
a)
If the host bus adapter connectors and FC-AL HUB connectors are of "LC"
type
Use the separately priced FC cable (NF9320-SJ0xE). Push the connector at
either end of the cable into the FC connector (HFx) for the host bus adapter of
either controller (CONT0 or CONT1) until a click is heard. The FC cable has
the same connectors at both ends. Either connector may be connected to the
controller.
Connect the connector at the other end of the FC cable to either FC-AL HUB.
Be sure to push the connector until a click is heard.
Pushing any connector excessively may injure the tip to decrease the
optical intensity, which will then cause malfunction to occur.
Similarly, connect the controller on the other array controller board to the
FC-AL HUB.
Connect the connector at one end of the FC cable to the connector for
connecting the host bus adapter installed in the host system, and the connector
at the other end to the above FC-AL HUB.
Be sure to push the connectors until a click is heard. The FC cable has the
same connectors at both ends. Either connector may be connected to the
FC-AL HUB.
Subsequently, connect the FC connector (HFx) for the other host bus adapter,
which is at the controller on each array controller board, to the other FC-AL
HUB via the FC cable.
Also connect the host bus adapter in the host system to the FC-AL HUB via the
FC cable.