8.10 Fault of Power Supply for Disk Enclosure

If the power supply for the disk enclosure is defected, the SERVICE LED on the array
controller lights orange. In addition, the SERVICE LED on the disk enclosure in which
the defected power supply is installed and the POWER FAULT LED on the defected
power supply are lit orange.
The defected power supply for the disk enclosure may be replaced with the powers of the
array controller and disk enclosure remaining ON.
<Replacement procedure>
(1) Turn off the power switch of the defected power supply for the disk enclosure.
Push down the power cord stopper toward the left, release the power cord stopper
from the receptacle of the power cord, and then remove the power cord.
When replacing a power supply for the disk enclosure, prepare the new
power supply before removing the old one, and then replace it within about 3
minutes.
The following are heating units of the disk enclosure:
A) Disk drives
B) Power supplies for the disk enclosure
The fans in the power supplies for the disk enclosure serve as cooling fans
for both of the above. Therefore, do not leave the disk enclosure with one of
the power supplies removed. Doing so causes the disk drive temperature to
rise, which may significantly decrease the reliability.