IMPORTANT:
For a disk to be inserted, use a new or physically formatted disk which has the same
capacity as the disk of the corresponding slot (in this example, the disk in slot 2 of the
PCI module 0)
When a disk is inserted, a popup window asking for rebooting the system may be
displayed, but there is no need to reboot it. Select [No] and close the popup window.
Insert the replacement disk after waiting for 15 seconds or more after removing a disk.
Inserted disk may not be configured to RDR automatically. If this occurs, right click on
the inserted disk in the left tree on [RDR Utility] and click [Add Physical Disk To RDR
Virtual Disk] to start synchronizing.
4.
Confirm that the DISK ACCESS LEDs and the display of RDR Utility change as shown
below:
Synchronizing
Source disk
Destination disk
RDR Virtual Disk
DISK ACCESS
LED
Amber
(Blinking)
Amber
(Blinking)
Windows Setup and Operation 3-21
RDR Utility
Op State: State
Simplex
Syncing
Simplex
Status
Resync x percent
(x=0, 4, 8, ..., 96)