7-22 Troubleshooting
default setting.
IMPORTANT:
After the operation, the BMC configuration for connecting to the DianaScope and to the
server will be lost. If you are already using the DianaScope, save the configuration on
FloppyDisk before this operation, then configure again. You can change/save the BMC
configuration on the system management function of DianaScope or EXPRESSBUILDER.
On the Network Connections screen, the numbering of the Local Area Connection
doesn't begin from "1":
operation. If you need to change the Local Area Connection name, right click the
icon on the Network Connections screen and select [Change name].
Wake On LAN does not function:
Does this happen to be right after the Alternate Current (AC) power supply started?
When you disconnect either or both of the AC cables on the server and the AC
supply is stopped, the Wake On LAN becomes unavailable on the next system
launch after the electricity supply starts. Connect the cables to both equipments
to supply the electriciy, and press the power switch to start the system.
Is the AC power supplied to both AC cables?
If the AC power supplied to only one of the AC cabled, Wake On LAN may
become unavailable. Supply the AC power supply to both of the AC cables, and
press the power switch to start the system.
Is the network adapter configured on OS?
→On the OS, go to [Start] - [Management Tool] - [Computer
This is because of the product feature and there this affects nothing on the
management] and select the Device Manager. Double click [Stratus
emb-EB 2-Port Gigabit Adapter #n] under the network adapter, then