4.
Restart the PCI module.
From the ft server utility, click [Up] of [Bring Up/Bring Down] to the PCI module
which was stopped in the step 3, and the PCI module will be started. Once the PCI
module is started, PCI module diagnosis, mirror volume duplication and PCI module
duplication are performed.
IMPORTANT:
If BrightStor ARCserve 2000 or Backup Exec is installed, the tape will not be
recognized due to the failover of the PCI module. Thus be sure to stop the services
before starting the PCI module.
1. Start [Services] from [Administrative Tools] of [Control Panel].
2. Select a service of backup software.
3. Choose "Stop" from the "Action" menu.
4. Repeat 2 and 3 for all services of the backup software.
The PCI modules' status LEDs changes as shown below:
[Indications of the status LEDs]
Immediately after the PCI module startup until the completion of diagnosis
CPU/IO module status LED1
1
2
CPU/IO module status LED2
3
DISK ACCESS LED
When duplication of disks is started after the completion of PCI module diagnosis
* The status of LEDs varies depending on the method of disk duplication.
LED
1
CPU/IO
LED1
2
CPU/IO
LED2
3
DISK ACCESS LED
After the completion of disk duplication and when the PCI modules are duplicated
1
CPU/IO module status LED1
2
CPU/IO module status LED2
3
DISK ACCESS LED
LED
module
status
module
status
blinking (when the disk
is accessed, this LED
illuminates in green)
LED
Windows Setup and Operation 3-35
Secondary
-
-
-
Amber or Green blinking
(when the disk is accessed,
this LED illuminates in
Secondary
-
Green blinking
Amber or Green
Secondary
-
Green
Green blinking
Primary
-
Green blinking
green)
Primary
-
Green blinking
Amber or Green
blinking (when the disk
is accessed, this LED
illuminates in green)
Primary
-
Green
Green blinking