Select [ftServer] - [CPU Module] - [(primary)CPU Module(*)]. The screen of the CPU
Module(to be removed) will appear.
Select [CPU Module Start/Stop] - [Stop] to the stop of the CPU Module.
*As for the CPU module to be stopped, select [CPU Module(ID:0)] to stop CPU module 0,
select [CPU Module(ID:1)] to stop CPU module 1.
When the CPU module is stopped, the status LEDs change as follows. This indicates that one
CPU module is operating now.
[Indications of status LEDs during diagnosis]
1
CPU/IO module status LED1
2
CPU/IO module status LED2
*Here, an example where CPU module 0 is stopped is shown.
3.
Start the stopped CPU module.
In the ft server utility, select the CPU module stopped in step 2 and click [Start] of [CPU
Module Start/Stop].
Once the CPU module is started, hardware diagnosis and then the duplication process are
performed.
Note that the system is paused temporarily for copying memory during memory
synchronization.
LED
ESX Server Operation and Configuration 3-7
Secondary*
Amber
-
Primary*
-
Green blinking