GE MDS entraNET 900 Technical Manual page 2

900 mhz and 2400 mhz extended range ip networking transceivers
Table of Contents

Advertisement

Quick Start Instructions
Listed below are the basic steps for installing GE MDS entraNET transceivers. Refer to the
appropriate sections in the manual for detailed information.
1.
Initial Checkout
• Set the equipment up in a tabletop arrangement as described in
EVALUATION,
(beginning on Page
• Follow all steps to ensure proper cable connections and unit configuration. As a minimum, Access
Points must have the following programmed: IP Address, IP Network identifier, and Radio Network
Address. (RF output power and Password should also be reviewed and set if necessary.) Remote
radios normally require only a Radio Network Address to be set. (Note: The Remote Radio Net-
work Address must match that of the AP.)
• Connect data equipment to the transceivers. Use LAN/ETH ports for Ethernet systems, or COM2
ports for Serial data systems.
• Verify proper exchange of data communications by viewing the LEDs. The following indications
should be seen on the LED panel within 30 seconds of startup:
PWR—Lit continuously
LINK—Lit continuously
ETH—Lit continuously (unless Sleep is activated)
COM2—Blinking to indicate exchange of data communications
2.
Endpoint Connectivity (PING) Test—for Ethernet Systems Only
• For Ethernet systems, verify the link integrity between the Access Point and endpoint devices con-
nected to Remotes by issuing a PING command from the AP. Below is a basic setup diagram for
the PING test. (NOTE: Endpoint devices must have a compatible IP address for this test to work.)
PC RUNNING PING UTILITY
3.
Set Configuration of AP and Remote Radios
• Refer to 3 AP MANAGEMENT
using the built-in menu system. Refer to 4 REMOTE RADIO MANAGEMENT
Page 99
for details on programming Remotes.
• If you have a large number of radios to configure, a configuration script may be used to speed the
process. See
USING CONFIGURATION SCRIPTS beginning on Page 181
4.
Install the Equipment in the Field
• Refer to 6 INSTALLATION
and antenna/feedline recommendations.
• After basic installation, optimize the performance of the radio network following the recommenda-
tions beginning on Page 160.
15).
ACCESS POINT
CROSS-OVER
CABLE
LAN
PORT
ETHERNET ENDPOINT
(Device Being Pinged)
beginning on Page 29
beginning on Page 147
2 TABLETOP SETUP AND
ETHERNET REMOTE
ETH
PORT
STRAIGHT THROUGH
Invisible place holder
for details on connecting to the AP and
for details on site selection, mounting, cabling,
CABLE
beginning on
for details.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds entranet 2400

Table of Contents