Point-To-Multipoint Ip-To-Serial Application Example - GE MDS iNET 900 Reference Manual

Mds inet series wireless ip/ethernet transceiver
Hide thumbs Also See for MDS iNET 900:
Table of Contents

Advertisement

05-2806A01, Rev. J
192.168.0.10
Ethernet
Crosssover
Computer
or Network
Figure 2-37. IP-to-Serial Application Diagram
Table 2-1. Serial Port Application Configuration
Transceiver
Location
Access Point
Remote Unit
2.6.7 Point-to-Multipoint IP-to-Serial Application
Example
The operation and data flow for this mode is very similar to
Point-to-Point serial-to-serial application, except that it uses multicast
addressing. The primary difference is that the PC uses UDP to commu-
nicate with all of the Remotes. Upon receiving the packet, each Remote
strips the data out of the UDP packet and sends it from its
Likewise, data presented at any of the Remotes'
etized, sent to the PC using the Access Point (see Figure 2-38 and
Table 2-2 on Page 73.
192.168.0.10
192.168.0.1
EIA-232
Access Point
Terminal
or Computer
Figure 2-38. Point-to-Multipoint IP-to-Serial Application Diagram
iNET Series Reference Manual
Invisible place holder
192.168.0.1
Access Point
IP-to-Serial Connection
Menu Item
None is required
IP Address
Status
IP Protocol
Baud Rate
Flow Control
Local IP Port
Invisible place holder
192.168.0.2
192.168.0.3
192.168.0.4
192.168.0.2
EIA-232
RTU
Remote
Setting
None is required
192.168.0.2
Enabled
TCP
9,600 (Example)
None
30011
port.
COM
ports is pack-
COM
EIA-232
Remote
RTU
EIA-232
RTU
Remote
EIA-232
Remote
RTU
73