Virtual Lan In Inet-Ii And Inet; Cyber Security Configuration - GE MDS iNET 900 Reference Manual

Mds inet series wireless ip/ethernet transceiver
Hide thumbs Also See for MDS iNET 900:
Table of Contents

Advertisement

05-2806A01, Rev. J
Table 2-4. Serial Port Application Configuration (Continued)
Transceiver Location
Remote Units 3 & 4
(COM2)

2.6.10 Virtual LAN in iNET-II and iNET

The iNET-II and iNET radios support port-based VLAN at the Ethernet
interface and over the air, as specified by the IEEE 802.1Q standard.
VLAN settings are made on the Network Interface Configuration Menu.
See Virtual LAN in iNET Series on Page 40 for more information
2.7 CYBER SECURITY
CONFIGURATION
The cyber security features of the transceiver are grouped into three gen-
eral areas: controlling access to the radio itself for configuration and
management purpose (Device Security), controlling how and when
radios communicate with each other, as well as how data traffic is han-
dled (Wireless Security) and a special section dealing with authentica-
tion and authorization using a central server (RADIUS Configuration).
Figure 2-42 shows the Security Configuration Menu, which is the entry
point for these categories.
iNET Series Reference Manual
Menu Item
Setting
IP Protocol
TCP
Receive on Port
30011
Status
Enabled
Baud Rate
9,600
Flow Control
Disabled
IP Protocol
UDP
Send to Address
IP address of the AP
Send to Port
30011
Receive on Port
30011
Receive on Address
224.254.1.1
(The multicast IP address used
for the AP's Send To Address
above)
77