View Current Alarms - GE MDS iNET 900 Reference Manual

Mds inet series wireless ip/ethernet transceiver
Hide thumbs Also See for MDS iNET 900:
Table of Contents

Advertisement

05-2806A01, Rev. J
(Telnet/Terminal only)
Filename
Log file sent to the TFTP server for archiving.
[
Any 40-char alphanumeric string; Blank
NOTE: You may want to change the filename to reflect the type
of log you intend to archive and/or its date.
TFTP Time-out
server will wait for a packet ACK (acknowledgment) from the
transceiver before canceling the file transfer.
[
10 to 120 seconds; 10
—IP address to which alarms are sent using the sys-
Syslog Server
log message format. [

View Current Alarms

Most events, classified as "critical" will make the
will inhibit normal operation of the transceiver. The LED will remain
blinking until the corrective action has been completed.
An alarm condition is different from a log event in the sense that an
alarm is persistent in nature. That is, an alarm condition remains as an
alarm until it has been cleared by correcting the cause (see Table 3-6 on
Page 123 for corrective action).
Figure 2-51. Current Alarms Screen
iNET Series Reference Manual
—Name to be given to the Event
—Time in seconds the TFTP
(Telnet/Terminal only)
]
Any valid IP address; 0.0.0.0
]
]
LED blink, and
PWR
89