Logged Events - GE MDS iNET 900 Reference Manual

Mds inet series wireless ip/ethernet transceiver
Hide thumbs Also See for MDS iNET 900:
Table of Contents

Advertisement

05-2806A01, Rev. J
Table 3-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry
Generating Condition
General System
Internal checks suggest unit
Error
is not functioning properly
Initialization Error
Unit fails to complete boot
cycle
Invalid IP Address
The IP address is either
0.0.0.0 or 127.0.0.1
MAC Failure
The monitor task reads the
LinkStatus from the MAC
every second. If the MAC
does not reply 10
consecutive times
(regardless of what the result
is) the CPU assumes the
transceiver has lost
communication to the MAC.
Network Interface
Unit does not recognize the
Error
LAN interface
Network Name Not
Network name is "Not
Programmed
Programmed"
PLL Out-of-Lock
The FPGA reports a
synthesizer out-of-lock
condition when monitored by
the CPU.
Power Control
Power control can no longer
Railed High
compensate and reaches the
high rail
Power Control
Power control can no longer
Railed Low
compensate and reaches the
low rail
RSSI Exceeds
The running-average RSSI
Threshold
level is weaker (more
negative) than the
user-defined value.

3.7 Logged Events

View Event Log on Page 90
(See
iNET Series Reference Manual
Clearing Condition
or Action
Reboot the transceiver
Contact factory Technical
Services for assistance
Program IP address to
something other than 0.0.0.0
or 127.0.0.1
Contact factory Technical
Services for assistance
Contact factory Technical
Services for assistance
Change Network Name to
something other than "Not
Programmed"
Contact factory Technical
Services for assistance.
Contact factory Technical
Services for assistance
Contact factory Technical
Services for assistance
Check aiming of the
directional antenna used at
the Remote; or raise the
threshold level to a stronger
(less-negative) value.
)
121