4.3.2

About data types transferred to the GOT

Data type
Boot OS
OS
Standard
monitor OS
(Required)
Communication
driver
(Required)
Extended
function OS
Option OS
Project data
(Required)
Special data
Resource data
Advanced recipe
function
List editor function
Gateway function
Recipe function
Standard font
(Chinese: Simplified,
traditional)
Multi-channel function
To operate the GOT, it is necessary to transfer the following types of data to the GOT.
The program needed to control GOT hardware, and during
communication between GOT and PCs.Boot OS is installed in
the GOT at factory shipment so installation is not usually
necessary.
The GOT monitoring function, OS/screen data installation,
OS/screen data deletion, touch key control, system screen/
guidance display function and other features for controlling the
GOT are installed.
The programs that operate the GOT, e.g. interface control,
OS/screen data installation, OS/project data deletion, touch key
control, and screen/guidance display functions.
The PC communication driver performs communication between
the GOT and the PLC CPU. Always select and install a PC
communication driver that is appropriate for the connection type.
Needs to be installed when the extended function *1 is used.
Needs to be installed when functions *
an option function board (including a board with extension
memory) or a multi-color display board are used.
Data for user-made monitor screens, such as screen data,
comments, common settings, etc.
Data used by the extended function (intelligent module/Q
motion/servo amplifier monitor, etc.).
All types of data created in the GOT main unit, such as recipe
file, alarm log file, etc.
*1 Extended functions included the following.
System monitor
*2 Option functions include the following.
Logging function
Object script
Network monitor function
Intelligent module monitor function
Maintenance report function
Point
With GOT, data exchange between the PC and GOT is expressed in the following
terms.
• Download : Writing the project data created by PC to the GOT.
• Upload
: Reading the GOT project data on a PC.
• Install
: Writing the system data required to run GOT (BootOS, OS) to
GOT.
Outline
2
available by connecting
Bar code
4 - 18
Data transfer timing
• When returning the
settings of the GOT main
unit to the factory
settings (normally,
installation is not required)
• When using GOT for the
first time
• When changing the
functions to be used
(Extended function, Option
OS) and communication
format
• After an OS upgrade
• When using GOT for the
first time
• When changing screens
and settings
• When
changing
functions to be used
• Varies depending on each
GOT function
Kana-kanji conversion
function
Ladder monitor function
Servo amplifier monitor
function
CNC monitor function
Q motion monitor function
the