Toshiba e-studio200l Service Manual page 313

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

[E]
Image position adjustment of the secondary scanning direction
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON. Æ (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
*Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5)
Check if the distance D is within the range of 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) Æ (Key in the code [305]) Æ [START]
Æ (Key in a value (acceptable values: 0 to 255))
Æ Press the [ENTER] or the [INTERRUPT] button (stored in memory).
Æ ("100% A" is displayed.)
*The larger the adjustment value is, the more the image is shifted to the trailing edge (0.14 mm/
step).
June 2004 © TOSHIBA TEC
Copied image of the ruler
10
20
D
Feeding direction
Fig.3-15
3 - 17
04/09
30
40
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT