3.12.3

Adjusting the overlap of the sensor flag

If the overlap between the sensor and the flag is wrong for some reason, perform the following adjust-
ment.
<Procedure>
(1)
Remove the processing tray unit.
(2)
Loosen the mounting screw of the front/rear
jogging plate adjusting plate; then, move the
adjusting plate to the left and the right.
(3)
Tighten the screw so that the overlap
between the flag of the front/rear jogging
rack plate and the sensor is 1.5 mm to 2.0
mm.
June 2004 © TOSHIBA TEC
Jogging plate
adjusting plate
Adjusting
plate
Screw
Jogging plate
adjusting plate
Fig.3-116
Sensor
1.5 mm to 2.0 mm
Fig.3-117
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT