Toshiba e-studio200l Service Manual page 454

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

[E420]
PFP side cover opened during printing
Is the PFP side cover open?
YES Æ Remove the paper if there is any, then close the cover.
È
NO
Is the PFP side cover opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]OFF/[2]/[F])
NO Æ
l
l
l
l
l
l
l
l
l
l
l
l
È
YES
1) Replace the PFP board.
2) Replace the LGC board.
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
1) Check if the connector of the PFP side cover opening/closing switch
is disconnected.
2) Check if either of the connectors CN241 or CN243 on the PFP board
is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
6) Replace the PFP side cover opening/closing switch.
7) Replace the PFP board.
8) Replace the LGC board.
5 - 24
June 2004 © TOSHIBA TEC

Hide quick links: