7.6.1.11 H-Pattern test
Test equipment: none.
Purpose: For EMI test.
Test Method: Show full black word "H" with white background.
Leave method: Touch pen, Serial port, Home button
7.6.1.12 EEPROM Information
Test equipment: PC, barcode scanner.
Purpose: Modify and Verify the EEPROM content.
Sub Menus:
1. Clear BOD
2. Write Serial Number
3. EEPROM information
4. Exit
Test Method:
1) Clear BOD: clear the BOD of the first 3 bytes in the EEPEOM.
2) Write Serial Number: get the barcode scanner by PC and send the data via HyperTerminal. DM receives
the data and writes it to the middle ten bytes in the EEPROM.
3) Show EEprom information: Get the 16 bytes EEPROM data and display it.
Leave method: Touch pen, Serial port, Home button
--- Provide EEprom information on message display area as below.