Chapter 2 Operating the Library
2.5 Configuring the Library
8
Click Next.
9
The Finish Configuration screen displays the proposed allocation of library resources into
partitions.
To update the configuration, click Back.
To have the wizard configure partition as shown, click Finish.
After the wizard reconfigures the partition, the library will come on line automatically.
To exit the wizard, click Cancel or Exit.
You can use the Expert Partition Wizard to adjust the allocation of resources after creating the partitions with
the Basic Partition Wizard. Moreover, you can enable or disable the drive auto cleaning function on the cre-
ated partitions.
2.5.13.2
Using the Expert Partition Wizard
Click Configuration > Partition > Expert Wizard to start the wizard. The Create Partition Scheme screen lists the
current partitions, if any, and the free resources. Use the wizard to configure one partition at a time.
If you want to enable or disable the mailslots, Cancel out of the wizard and update the mailslot configuration
before configuring partitioning.
Procedure
1
To add a partition, click Add and then click Next.
The Add button will only be active if there are available resources. If there are no available resources,
either edit a partition and release resources from it or remove a partition that contains extra
resources.
2
Enter a name for the partition.
3
Select the number of barcode characters reported to the host application.
This option provides interchange compatibility with libraries with more limited barcode reading capa-
bilities. The maximum length is 15 and the default is 8. This configuration will apply to all partitions.
The industry standard length for LTO barcode labels is eight characters. Barcode labels longer than
eight characters might scan incorrectly, particularly if they are not high quality labels.
FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Panel Operation-
44
Copyright 2016 FUJITSU LIMITED
End of procedure
P3AM-8802-04ENZ0