Chapter 2 Operating the Library
2.6 Maintaining the Library
To run the element test
Procedure
1
Navigate to the Maintenance > Library Tests > Element to Element Test screen.
2
Select a cartridge from the Source Elements list.
To select from a subset of the cartridges:
a Click Filter On.
b Enter characters into the search box and then click Search.
The Source Elements list is updated to only include cartridges with a barcode label including the
search characters.
3
Select a location from the Destination Elements list.
4
Select the number of cycles.
5
Click Start Test.
2.6.1.4
Position Test
The position test moves the robotic assembly vertically between two elements. The number of movements
can be specified.
This test does not move cartridges.
FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Panel Operation-
50
Copyright 2016 FUJITSU LIMITED
End of procedure
P3AM-8802-04ENZ0