Chapter 2 Operating the Library

2.6 Maintaining the Library

2.6
Maintaining the Library
From the Home screen click or tap on Maintenance to access the library maintenance features.
2.6.1

Library Tests

2.6.1.1
System Test
The system test exercises overall library functionality by moving cartridges within the library.
During each cycle the library will move a cartridge from a full slot to an empty slot and then return it to its
original slot. You can select the number of cycles for the test. If the test is canceled, the library will return
the cartridge to its original slot.
The library will not move cleaning cartridges during the test.
The test operates over the whole library and does not take into account partition configuration.
During the test the library is off line.
To run the system test, navigate to the Maintenance > Library Tests > System Test screen, select the number of
cycles and then click Start Test.

Figure 2.22 System test

2.6.1.2
Slot to Slot Test
The slot to slot test randomly exchanges cartridges between slots to verify that the library is operating cor-
rectly. At the end of the test the cartridges are NOT returned to their original slots. If a tape is moved to an
incompatibly drive, the drive will reject the tape, as designed.
The test can move cartridges between partitions.
FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Panel Operation-