1.6 Trunk/Extension Cabling

1.6.1 General

The system provides RJ61 modular jacks for analog trunk and analog/digital extension connections.

1.6.2 Precautions for Cabling

• Do not wire the cable with an AC cable, computer, etc.
• Do not run the cable near a high frequency generating device.
• Use cable protectors in case the cables are run on the floor.
• Aerial distribution wiring is not allowed.
• Trunks must be installed with lightning protectors.
• Do not install the DSX Terminal in the SL1100 system, it does not work properly.

1.6.3 Trunk Cabling

Trunk cabling is required for the 4COIDB or 1PRIU PCBs.
Refer to
INSTALLING THE EXPANSION INTERFACE CARDS on page 2-42
4COIDB and 1PRIU PCBs.

1.6.4 Extension Cabling

The 084M-B1 PCB within each KSU provides two "RJ61" modular jacks for digital extension (8ports)
and one for analog extensions (4ports).
Before plugging in the Multiline Telephone, DSS Console, Single line
Telephone or Doorphone, ensure all Main and Expansion KSUs are powered
off.