Step by step
ehm
emm
Independently from the system password, an additional
password can be defined for enabling/deenabling differ-
ent features (e.g., night service, relays). The default
password is "31994." This password can be changed.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
p
Enter a new system password (5 digits).
w
Initial status for programming mode.

Restoring Default Settings

You can delete the settings that have been configured
and restore the default settings. Only Country/group of
countries settings (Code 65) will be saved as last con-
figured.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
p
Enter the system password (default is 31994).
w
The system restarts.

HiPath 1120 Alarms

You can assign an alarm to a system sensor. When the
alarm is triggered, the system dials the number stored
as entry 249 in the speed dialing phonebook (the name
assigned to this entry can be up to 15 characters long.
For example, it can be the name of an emergency sta-
tion).
The system ID is automatically sent and continues to be
sent to the station called until the service requested re-
turns the "#" digit, acknowledging the alarm "#". This
works as a confirmation that the service has detected
the alarm call sent by the system.
If a Fax/DID module is installed, you can send an alarm
message in addition to the Exchange ID.