Using HP-113 or HP-IL Interface
HP 1630G Learn String Format (for Time Interval Overview)
SYNTAX : TS;
Starting Byte
Number
Position
Of
In String
Bytes
Contents
NOTE
The binary value of these bytes is the number of bytes to follow including the
CRC check bytes. This value is transmitted as MSB first and LSB last. The
maximum byte count is 162 .
Model 1630A/D/G
1
2
(A) AS (Accept State Command)
3
2
(I) Binary byte count (refer to Note)
CRC STARTS ACCUMULATING WITH NEXT BYTE
5
7
(I,B) Date/Time information
12
1
(S) This is time positional data
13
1
(S) Count all states, not time between states
14
1
(S) Counter values already converted to
floating point
15
4
(R) Time positional measurement period
in seconds
19
1
(S) Overview was program activity, not
all states
20
1
(I) Type of data (2 = State Time Interval)
21
4
(R) Total number of samples
25
4
(R) Total accumulated time
29
4
(R) Minimum interval found
33
4
(R) Maximum interval found
37
4
(R) Average time of interval
41
4
(R) Time of last interval acquired
45
8
Internal
53
112
(I) Data acquired from 8 time interval ranges-
fewer bytes if less than 8 ranges
Each time interval range contains :
2
Internal
4
(R) Number of samples in this range
4
(R) End time of this range
4
(R) Start time of this range
165
2
(I) CRC