TE - Transmit Everything Learn String
The transmit everything learn string command instructs the analyzerto transmit the following data in the listed
sequence : (1) configuration learn string, (2) state data acquisition learn string, and (3) timing data acquisition
learn string . Refer to the TC, TS, and TT command descriptions for learn string formats . The maximum number
of bytes will be the sum of the bytes of the individual commands. The maximum number of bytes (5476) will
occur in the combined State/Timing Mode .
DATA TRANSFER TERMINATION
Binary transfers of data are terminated by setting EOI true with the last byte transferred . Non-binary transfers
are terminated by sending CR LF with EOI true .