(5) Test mode
(a) Set whether to operate the job in test mode or not.
Up to 4 jobs can be set to [Test mode].
When the [Test mode] box is checked, the test mode is activated, and execution details of the job can be
confirmed before operation.
Job execution can be confirmed in [Job Execute Log] on the [Working log] tab.
(b) When [Test mode] is selected
The following are performed in the test mode.
Operations other than the following are identical to the actual operations.
• Startup data are logged.
• Detailed data are logged.
• Data are not written to GOT devices.
• No data are written to the database.