Mitsubishi Electric GOT 1000 Series Manual page 48

Graphic operation terminal
Hide thumbs Also See for GOT 1000 Series:
Table of Contents

Advertisement

*1
*2
*3
*4
*5
*6
*7
*8
(2) Starting the GOT
Preparation of the GOT
Mount the option function board on the
*1
GOT.
Connect to Ethernet.
Install a CF card.
(Only when needed)
*1
*2
*3
*4
4 - 2
4.1 Settings and Procedures before Use of the MES Interface Function
Be sure to make the settings to use the DB interface function.
5.1 DB Interface Function
Make the settings when using the program execution function.
5.1.9 Program execution function
Make the settings when using the time on the SNTP server computer with the SNTP time synchronization function.
5.2 SNTP Time Synchronization Function
Restart the personal computer after installing the relational database.
Communication with GOT may fail if not restarted.
Create it only when necessary.
An existing program, a program included in OS, or a commercially available program can also be used.
Always set a password for the account for user program execution.
Use of an account without password will result in execution failure by OS.
If the login is not confirmed, the program execution function may not operate properly.
When installing DB Connection Service and DB Connection Service Setting Tool, log in using a user name with administrative
right.
Do not log in the server computer using an account for user program execution during user program execution.
Doing so may cause incorrect operation of the program execution function.
Procedure for starting GOT
*2
Connect the GOT to the configuration computer.
(USB, RS-232, Ethernet)
Operation start
For GT16, use the MES interface function board.
For GT15, use the option function board with MES interface function.
For GT16, use the built-in Ethernet interface.
For connecting GT16 to a device supporting 10BASE(-T/2/5), configure the network that supports both 10Mbps and 100Mbps
communication speeds by using a switching hub.
For GT15, mount the Ethernet communication unit.
Configure the Extend I/F Setting in Communication Settings of GT Designer3.
In the Extend I/F Setting, select any of the following and set an IP address.
• CH: * Driver: Ethernet download
• CH: * Driver: Gateway
• CH: 1 Driver: Ethernet(MELSEC), Q17nNC, CRnD-700
• CH: 1 Driver: Ethernet(MELSEC), Q17nNC, CRnD-700,Gateway
When using the MES interface function only on the Ethernet, the GOT port No. setting in Communication Detail Settings is
ignored.
In Ethernet connection, the option OS cannot be installed.
To install the option OS, use USB or RS-232 connection.
On the configuration computer
Install GT Designer3.
*3
Create project data.
Configure MES interface settings.
*4
Install the option OS on the GOT.
(Including MES interface)
Download the project data to the GOT.
(Including MES interface settings)

Hide quick links: