Error code
0x20600010
0x20600020
0x20600021
0x20600022
0x20600023
0x20600025
0x2060002B
0x20700001
0x20700002
0x20700010
8 - 16
8.2 Error Code List
Error description and cause
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Invalid SQL execution request
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
DB Connection Service does not support the SQL
instruction to be executed.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in preparation before SQL execution.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed to obtain the number of fields in the record that is to
be obtained by the SQL execution.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
No record was updated or inserted by the SQL execution.
(SID [Session ID]: *** Transmitting Commit Success
Response Failed. ***)
Failed to transmit the COMMIT success response.
(ProgramExec: [IP address]: <...>: Failed)
Failed in remote execution due to insufficient memory.
(ProgramExec: [IP address]: <...>: Failed)
Failed in remote execution due to insufficient resources.
(ProgramExec: [IP address]: <...>: Failed)
Invalid remote execution request
Corrective action
• Check the source IP address setting.
• Confirm the version of the option OS (MES Interface).
• Correctly set a database type for [DB server setting], a
table name in the job for the communication action
setting, or the resource data send action setting in
[MES Interface].
6.6 Server Service Settings
• Correctly set a database type for [DB server setting], a
table name, field names, Select/Update conditions, and
types of the data to be stored in the fields in the job for
the communication action setting or the resource data
send action setting in [MES Interface].
6.6 Server Service Settings
• In [MES interface setting], set update conditions
correctly for the Communication action setting of the
Job settings.
6.8.1 Setting items in Communication action
• Check if the database has been filled with registered
data.
• Check if it is connected to the network.
• Check if the gateway and/or hub is operating.
• Check if the power of the GOT has not been turned off.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Check the source IP address setting.
• Confirm the version of the option OS (MES Interface).
(To the next page)