Program 80 : Basic Hardware Setup For System; Service Tone Setup; Table 2-14 Basic Tones - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 3.01

Program 80 : Basic Hardware Setup for System

Level:
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is
defined by the combination of 32 Basic Tones.
Input Data
Service Tone Number
Item
Item
No.
01
Repeat Count
Item
Item
No.
02
Basic Tone Number
03
Duration Count
04
Gain Level (dB)
Basic Tone No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Programming Manual
0 ~ 255 (0 = Endless)
Unit Number
0 ~ 33
(0 = No Tone)
(33 = Default Time Slot)
0 ~ 255 (0, 100 ~ 25500 ms)
0 ~ 63 (- 15.5 ~ + 15.5)

Table 2-14 Basic Tones

Frequency (Hz)
420
520
580
660
700
800
880
1050
430
440 / 480
480 / 620
440
-- Reserve --
520 / 650

80-01 : Service Tone Setup

01 ~ 64
Input Data
1 ~ 8
Input Data
Level (dB)
- 13 / - 13
- 13 / - 13
SL1000/SL1100
Default
Refer below
Default
Refer below
Refer below
Refer below
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 13
-16
-
-19 / -13
2-457
Program
80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents