Alarm
Re-
Type
Name
No.
port
3
2
0
Connec-
tion fault
between
CPU and
other
PKGs.
4
2
0
PKG S/W
Download
Error
Programming Manual
Content of
Cause
Alarm
The error occur-
1.
The unit is not
red when com-
completely in-
municating with
serted.
the package.
2.
The power-
When the pack-
supply voltage
age is broken, it
of the system
recognizes it as
is outside rat-
a communica-
ings.
tion fault.
3.
The equip-
ment that gen-
erates the
noise in the
same power
supply system
as the power
supply origin
of the system
is connected,
and it malfunc-
tions because
of the power
supply noise.
4.
The equip-
ment to which
it is adjacent
to of a main
device, and
has put out
the radiation
noise exists,
and it malfunc-
tions because
of the radia-
tion noise.
5.
The chassis is
not properly
grounded.
The unit pro-
1.
The package
gram could not
software is not
be downloaded
stored in the
normally.
downloaded
The unit could
USB memory.
not able to be
2.
The stored
started normal-
package soft-
ly.
ware is illegal.
Package infor-
mation that
was installed
before re-
mains.
SL1000/SL1100
Action
Recovery
1.
Please insert
When unit is
the unit firmly.
confirmed,
2.
The power-
the error is
supply voltage
recovered.
must use an-
other power
supply when is
in the range of
ratings or
measuring
with the volt-
meter, and de-
viating from
the rated
range.
3.
Please use the
power supply
besides the
equipment
with the possi-
bility of the
noise source.
4.
Please sepa-
rate as much
as possible
and use a
main device
from the
equipment by
which you
seem may
generate the
radiation
noise.
5.
Please ground
the chassis
correctly.
1.
Delete slot in-
Please ex-
formation that
change units,
corresponds
though it is
by Program
likely to re-
90-05-01 to
store by
delete pack-
mounting the
age informa-
unit again.
tion that was
When the unit
installed be-
program is
fore.
normally
2.
There is a
downloaded,
possibility that
the error is
the unit pro-
recovered.
gram is broken
though an ex-
ternal factor of
the noise etc.
is thought.
3.
Please load in-
to the USB
memory and
try again when
you back up
the unit pro-
gram.
4.
Please Check
with maker on
uncertain
points.
Alarm
Status
ERR
REC
Program
90
ERR
REC
2-559