ISSUE 3.01
Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use Program 80-11 : MFC Tone Receiver Setup to various data for the MFC signal detection.
Input Data
MFC Tone Receiver Type Number
Item
Item
No.
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Twist level
06
S/N ratio
07
ON detect time
08
OFF detect time
Programming Manual
80-11 : MFC Tone Receiver Setup
1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
Input Data
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (0.25 step, 0 ms ~ 64 ms)
0 ~ 15
detect level 0 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 1 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 2 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 3 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 4 = - 30 dBm (0) ~ - 45 dBm (15)
detect level 5 = - 35 dBm (0) ~ - 50 dBm (15)
detect level 6 = - 40 dBm (0) ~ - 55 dBm (15)
0 ~ 15
detect level 0 = 0 dBm (0) ~ - 15 dBm (15)
detect level 1 = - 5 dBm (0) ~ - 20 dBm (15)
detect level 2 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 3 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 4 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 5 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 6 = - 30 dBm (0) ~ - 45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
0 ~ 4 (- 5 step, 0 dB ~ - 20 dB)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
SL1000/SL1100
3 = Reserved
4 = Reserved
5 = Reserved
Default
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
2-473
Program
80