NEC SL 1000 Programming Manual page 582

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Alarm
Type
No.
6
Program
90
8
10
11
14
17
18
2-560
Re-
Content of
Name
port
Alarm
0
0
Blocking
The link of ter-
minals connec-
ted with the ESI
package came
off.
1
0
RAM
RAM backup
Backup
battery on the
Battery
CPU unit is un-
Error
plugged or de-
fective.
0
0
ISDN Link
Layer1 link of
Error
ISDN lines
came off.
0
0
CTI Link
The link with the
Error
CTI server
came off.
0
0
LAN Link
The link with
Error
LAN on CPU
came off.
1
0
Denial of
The system re-
service
ceived illegal
packet.
1
0
Connec-
Digital Station
tion Error
Wiring Error
Cause
Action
1.
Terminal
Confirm the termi-
Breakdown.
nal connected with
2.
Faulty wiring
same ESI. If they
and wiring ter-
work normally,
mination.
confirm the break-
3.
External
down or the wiring
noise.
for the terminal.
4.
ESI package
Exchange the ter-
Breakdown.
minal that doesn't
work and the work-
ing terminal, and
confirm it's work-
ing. An external
factor of the noise
etc. is thought.
Please reconfirm
wiring and the in-
stallation, etc.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
Check the battery
connector. If it is
connected correct-
ly, replace the bat-
tery.
1.
Check Con-
1.
Confirm the
nection be-
data of Pro-
tween main
gram 10-03.
device and
2.
Confirm wiring
ISDN line.
and the instal-
2.
DSU Break-
lation of DSU.
down.
3.
Check with the
3.
The setting of
manufacturer
Program
if the problem
10-03 does
occurs again.
not corre-
spond to an
actual line.
1.
LAN cable de-
1.
Confirm the
fective.
CTI server,
2.
Connected
wiring, and the
HUB broken.
connection.
3.
The CTI serv-
2.
Check the
er doesn't
manufacturer
start normally.
if the problem
occurs again.
1.
LAN cable de-
Confirm the opera-
fective.
tion of LAN con-
2.
Connected
nector, LAN cable,
HUB broken.
and HUB again.
3.
Defective
CPU.
Service outage
Confirm whether to
(Dos attack)
find abnormality on
the net side.
The wiring connec-
Check all wiring in
tion between the
between the Multi-
Multiline terminal
line terminal and
and the system
the digital station
has an issue.
card.
Program 90 : Maintenance Program
ISSUE 3.01
Alarm
Recovery
Status
The error is
ERR
recovered
REC
when con-
necting or ex-
changing it.
The error is
ERR
recovered
REC
once the bat-
tery is re-
placed.
When the
ERR
connection
REC
returns nor-
mally, the er-
ror is recov-
ered.
When the
ERR
connection
REC
returns nor-
mally, the er-
ror is recov-
ered.
When the
ERR
connection
REC
returns nor-
mally, the er-
ror is recov-
ered.
WAR
MAJ

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents