Program 10 : System Configuration Setup
Level:
IN
Description
Use Program 10-26 : IP System Operation Setup to enable or disable the Peer to Peer feature for
SIP MLT and SIP IP stations.
Input Data
Item
Item
No.
02
RTP Forwarding
Mode
03
SIP Peer to Peer
Mode
04
DR700 Peer to Peer
Mode
05
SIP CTI Mode
Conditions
• Disabling 10-26-04 results in SIP MLT Station-to-SIP MLT Station calls using a DSP resource.
• SIP-to-SIP MLT Station does not support Peer to Peer function and will result in using a DSP
resource.
• Disabling 10-26-03 results in SIP IP Station-to-SIP IP Station calls using a DSP resource.
Feature Cross Reference
None
Programming Manual

10-26 : IP System Operation Setup

Input Data
0 = Disable
1 = Enable
0 = Off
1 = On
0 = Off
1 = On
0 = Disable
When SIP CTI Mode is set as 1 (Mode1) it
1 = Mode1
will ignore the setting at 10-26-03.
SL1000/SL1100
Description
Program
10
Default
0
1
1
0
2-33