4.5.3.
Document Jam (030) or Skew
Edition 1.0
START
Is the Control Panel Unit
closed?
Yes
Do all sensors on the PNL1
PCB operate normally?
Yes
Does the Feed Roller have
drive and sufficient friction?
Yes
Is the document path clear
of foreign particles or paper?
Yes
Is the Transmitting
mechanism operating
properly?
Yes
END
126
No
Close the Control Panel Unit
firmly.
No
Clean or replace PNL1 PCB.
No
Clean the surface of roller
with isopropyl alcohol
(Sect.2.2.4).
No
Remove the foreign particles
or papers from the document
path.
No
Adjust or replace any
defective parts.