Panasonic DX-600 Service Manual page 162

Hide thumbs Also See for DX-600:
Table of Contents

Advertisement

No.
Parameter
123
Not Used
~
129
130 BUSY-ACK
TIMING
131 CMD RCV GRD
TIMER
132 PRT DATA
TIMER
133 COLLATION
(PRT)
134 COLLATION
(PC I/F)
135
Not Used
~
199
Note 1: Function Parameter No. 070 (Line Error) - Transmit condition of RTP/PIP or RTN/PIN
Signal
MCF/PIP
RTP/PIP
RTN/PIN
Note 2: Function Parameter No. 071 (Total Error) - Transmit condition of RTP/PIP or RTN/PIN
Note 3: The default setting of parameters depends on the destination's specifications or regulations.
Print the Function Parameter List to confirm the default settings.
Note 4:
Continuous Polling (Station Mode)
This feature allows you to store or add documents into a polled file in memory.
To enable the Continuous Polling feature set Function Parameter No. 003 to "2:Station". The Program
Key [P4] will be assigned with the "Store-4-Polling" name automatically and cannot be changed.
To prepare the document(s) to be polled, simply place the document(s) on the ADF and then press the
Program Key [P4] to store or add the document(s) into a polled file.
(Note: If a regular polled file ([FUNCTION][3][2]) is stored in memory, the Program Key [P4] for
Continuous Polling will not be accepted.)
Edition 1.0
Service Mode 1 : Function Parameter Table
Selections
• In Busy
• After Busy
• While Busy
1 min.
~
15 min.
1 min.
~
15 min.
1 = Off
2 = On
3 = Auto
1 = Off
2 = On
3 = Auto
1:128
2:256
0-31
0-63
32-63
64-127
64-127
128-255
Signal
1:5%
MCF/PIP
0-2
RTP/PIP
3-4
RTN/PIN
5-
Selects the signal timing between the BUSY and
ACK signal in Printer Interface Mode.
Selects the Guard Timer between each GDI
Command in Printer Interface Mode.
Selects the Guard Timer between each GDI Data
Frame in Printer Interface Mode.
Selects the Print Collation in Printer Interface Mode.
When "Auto" is selected, print collation will operate
according to the setting in Fax Parameter #65.
Selects the Print Collation in PC Interface Mode.
When "Auto" is selected, print collation will operate
according to the setting in Fax Parameter #65.
Setting
3:512
4:1024
0-127
0-255
128-255
256-511
256-511
512-1023
Setting
2:10%
3:15%
0-4
0-7
5-9
8-14
10-
15-
162
Function
5:2048
6:Off
0-511
Always
512-1023
-
1024-2047
-
4:20%
0-9
10-19
20-
DX-600/800
APR 2002

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx-800

Table of Contents