Code
Mode
502
XMT/
RCV(V.34)
540
XMT ECM
541
XMT ECM
542
XMT ECM
543
XMT ECM
544
XMT ECM
550
RCV ECM
554
RCV ECM
555
RCV ECM
580
XMT
581
XMT
601
XMT
623
XMT
630 XMT or RCV
(Polling)
631
XMT
634
XMT
638
XMT
Edition 1.0
Fax Information Codes
Phase
Description of Problem
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
B
No response after transmitting 3rd
CTC or DCN received.
D
No response after transmitting 3rd
EOR or received DCN.
D
No response to the 3rd RR
transmitted or received DCN.
D
T5 timer (60 sec.) elapsed without
MCF.
D
Stopped Transmission after EOR
Transmission.
C
Timer between frames in phase C
has elapsed.
D
Transmitted ERR after receiving
EOR.
D
Transmitted PIN after receiving
EOR.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
ADF Door was opened during ADF
transmission.
A
No original was in the ADF. (Built-
in dialer engaged)
B
Redial count over.
A
"STOP" button was pressed during
Auto Dialing.
B
Redial count over with no
response or busy tone was not
detected.
Note:
U.S.A. and Canadian models
will redial only once if a busy
tone is not detected.
LAN
Power turned Off with applicable
data in memory or during
communication.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB are defective.
Incompatible interface.
Line is faulty.
MJR PCB abnormal.
Remote unit is abnormal.
Remote unit is abnormal.
Line is faulty.
MJR PCB abnormal.
Defective remote station.
Line is faulty.
Line is faulty and Operator Call
requested by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
No dial tone detected. Sensor dial tone
is not detected. (destination dependent)
Busy tone is detected. (destination
dependent) T1 timer (35 ± 5 sec.)
elapsed without a signal from the
receiver.
Telephone line cable is disconnected.
Wrong number is dialed.
SC or MJR PCB is abnormal.
Power switched off.
Power failure occurred.
144