CN6
SC PCB
Signal Name
Pin No.
CN6-1
+24V
CN6-2
+24V
CN6-3
GND
CN6-4
GND
CN6-5
GND
CN6-6
+3.3V
CN6-7
+5V
CN6-8
-5V
CN6-9
+5VP
CN6-10
nMPOFF
CN6-11
nSSR
Edition 1.0
Destination
POWER SUPPLY
UNIT
CN103-1
POWER SUPPLY
UNIT
CN103-2
POWER SUPPLY
UNIT
CN103-3
POWER SUPPLY
UNIT
CN103-4
POWER SUPPLY
UNIT
CN103-5
POWER SUPPLY
UNIT
CN103-6
POWER SUPPLY
UNIT
CN103-7
POWER SUPPLY
UNIT
CN103-8
POWER SUPPLY
UNIT
CN103-9
POWER SUPPLY
UNIT
CN103-10
POWER SUPPLY
UNIT
CN103-11
Signal Waveform
+24V
+24V
0V
0V
0V
+3.3V
+5V
-5V
+5V
+6 7V
(Energy Saver Mode)
Fuser Lamp
ON
61
Function
+24 VDC Power Supply
+24 VDC Power Supply
Ground
Ground
Ground
+3.3 VDC Power Supply
+5 VDC Power Supply
-5 VDC Power Supply
+5 VDC Pilot Power Supply,
that provides power to the
active components during
the Sleep Mode.
Energy Saver Mode Control
Signal
0V
Fuser Lamp Control Signal