Toshiba e-STUDIO163 Service Manual page 139

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:
Table of Contents

Advertisement

[G] Bypass sensor (S8)
(1)
Remove 2 screws on the bottom of the
equipment.
(2)
Disconnect 1 connector and take off the
bypass sensor with the bracket.
(3)
Release 2 latches and take off the bypass
sensor.
[H] Bypass pickup solenoid (SOL2)
(1)
Take off the bypass unit.
P.10-8 "[A] Bypass unit"
(2)
Remove 1 screw.
December 2005 © TOSHIBA TEC
Bracket
Fig. 10-19
Bypass sensor
Fig. 10-20
Bypass unit
Fig. 10-21
e-STUDIO163/203 PAPER FEEDING SYSTEM
10 - 13
Connector
Bracket
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio203

Table of Contents