[C] Filling developer unit with developer material
(1)
Install the developer nozzle jig on the devel-
oper bottle.
(2)
Rotate the gear on the rear side of the devel-
oper unit to the direction of the arrow while
filling the developer unit with the developer
material. Spread out the developer material
over the developer sleeve.
[D] Auto-toner sensor (S6)
(1)
Remove the developer material.
P.12-11 "[B] Removing developer mate-
rial"
(2)
Place the developer unit upside down.
Disconnect 1 connector, release 1 latch, and
then rotate the auto toner sensor counter-
clockwise to take it off.
e-STUDIO163/203 DEVELOPMENT SYSTEM
Lid
12 - 12
Fig. 12-11
Connector
Auto toner sensor
Fig. 12-12