[J]
Drum separation finger
(1)
Take off the drum.
P.11-14 "[H] Drum"
(2)
Take off 2 drum separation finger units by
removing 1 screw each.
Note:
When replacing the drum separation fingers,
make sure that the drum has been taken off
first since the fingers may scratch the drum
surface.
(3)
Remove the spring and take off the drum
separation fingers.
Note:
When the drum separation fingers have been
replaced, check if the pressure movement is
normal by moving them with your hands.
[K] Recovery blade
(1)
Take off 2 drum separation finger units.
P.11-15 "[J] Drum separation finger"
(2)
Remove 2 screws, and take off the whole
recovery blade with the bracket.
December 2005 © TOSHIBA TEC
Drum separation finger unit
Fig. 11-20
Drum separation finger
Fig. 11-21
Recovery blade
Fig. 11-22
e-STUDIO163/203 DRUM RELATED SECTION