Hitachi IJ RX2 Service Manual page 198

Hide thumbs Also See for IJ RX2:
Table of Contents

Advertisement

6.2.18 Ink Heating Unit Over Current
Ink Heating Unit
Over Current
Is the PTC resistance
measured (between the
EZJ125 board TP3 and TP15)
lower than 23 ?
Yes
Replace the heating unit.
▪ Clear the fault.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Does the fault recur?
Yes
Replace the EZJ125 board.
▪ Clear the fault.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Does the fault recur?
Yes
Replace the EZJ126 board.
▪ Clear the fault.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Does the fault recur?
Yes
Replace the print head.
- On detecting this fault, the IJ printer automatically sets the "Ink temperature
correction" to (disable).
"System environment setup: Ink temperature correction (enable)  (disable)"
After getting rid of the fault, reset the Ink temperature correction to (enable).
"System environment setup: Ink temperature correction (disable)  (enable)"
- In the condition of the "Ink temperature correction (disable), " the "Ink Temperature
Correction Notice" message appears each time the power is turned on.
(See "1.6 Heating of Ink" in the Instruction manual".)
No
*) Refer to the
following caution.
No
*) Refer to the
following caution.
No
*) Refer to the
following caution.
No
Resume the
operation.
Caution
!
6-19