(2) Automatic ink replenishment data (AUTOSPLY.TXT)
Control
№ Date
Start time
sequence
1 2011/7/7
0:02:49 High
2 2011/7/7
0:03:59 Norm.
3 2011/7/7
0:04:36 Norm.
4 2011/7/7
0:07:43 Norm.
5 2011/7/7
0:11:11 Low
6 2011/7/7
0:22:33 Norm.
7 2011/7/7
0:30:55 Norm.
8 2011/7/7
0:31:22 Norm.
- Control sequence
Norm. : Normal ink concentration
Low : Performing the reducing concentration control due to the high ink concentration
High : Performing the increasing concentration control due to the low ink concentration
- Initial level (High-speed machine)
The position of initial level at the high-speed machine (1 to 3) (0: At the other model)
- Mode
Result of Automatic ink replenishment (Refer to the next page (3).)
- Ambient temperature
Ambient temperature measured by the sensor in the neck of Printhead
- Viscometer temperature
Ink temperature measured by the sensor in the viscometer
- Dot count
The number of printed ink dots during the each ink replenishment interval
- Ink replenishment (for dot count)
Ink replenishment for printed ink dots (Replenishment time; Hour:Minute:Second)
- Makeup replenishment (to an initial level)
Makeup replenishment to the initial level (Replenishment time; Hour:Minute:Second)
- Ink replenishment (to an initial level)
Ink replenishment to the initial level (Replenishment time; Hour:Minute:Second)
- Finish time
Finished time of replenishment (Hour:Minute:Second)
Ink
Sequence
Concent-
ration
Normal
Normal ink
concentration
Low
Increasing
concentration
control
High
Reducing
concentration
control
(*1) In case of "Dot count < 65,536 dot", ink replenishment is not performed and the dot count value
is added to next count.
(*2) Ink replenishment amount is the equivalent amount of Dot count – 3.2ml. In case of minus value,
ink replenishment is not performed.
[Example]
Initial level
(High-
speed
Ambient
Viscometer
machine) Mode
temperature
temperature
1
2
26
1
3
26
-
B
26
-
2
26
1
3
26
-
B
26
-
2
26
-
G
26
<Process of ink replenishment control>
Initial level sensor: OFF
(1) Ink replenishment (for dot count (*1))
(2) Makeup replenishment
(to the initial level)
(1) Ink replenishment (for dot count (*1))
(2) Ink replenishment (to the initial level)
(No makeup replenishment)
(1) Ink replenishment (*2)
(2) Makeup replenishment
(to the initial level)
Ink
replenishment
Ink
Cumulative
(for dot
Pressure
print count Dot count
count)
23
0.297
0
0
23
0.257
0
0
23
0.256
17
1292
23
0.299
24
214
23
0.298
43
7572
23
0.256
58
10212
23
0.299
60
0
25
0.249
65
5655
2-52
Makeup ink
Ink
replenishment
replenishment
(to an initial
(to an initial
level)
level)
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00
TimeOver
0:00:00
Initial level sensor: ON
(1) Ink replenishment
(for dot count(*1))
(No makeup replenishment)
No replenishment
No replenishment
Finish time
0:02:49
0:03:59
0:04:36
0:07:43
0:11:11
0:22:33
0:30:55
0:31:52