Hitachi IJ RX2 Service Manual page 243

Hide thumbs Also See for IJ RX2:
Table of Contents

Advertisement

6.5.19 Power Restoration Procedure
Power Restoration
Procedure
Is the EZJ126 board
CN1 connector
disconnected or in
poor contact?
Is the EZJ128 board
CN1 connector
disconnected or in
poor contact?
Replace the EZJ128 board
Does the fault recur?
Replace the EZJ126 board.
Resume the
operation.
Yes
No
Yes
No
No
Yes
6-64
Normality is restored when the
connector is disconnected and then
reconnected.