2.2 System environment setup

The setting with respect to the system environment of the IJ printer is performed.
Ink type
Nozzle size
Excitation frequency
Ambient temperature upper limit
Excitation setting (Max.)
A "USB memory containing system data" is needed to set nozzle size.
This setting is performed in the IJ printer "Stop" state.
1 The maintenance menu is displayed.
If Prev. menu Next menu is not displayed on the maintenance menu, set the service
personnel maintenance mode on the login user selection screen.
For information on changing to the service personnel maintenance mode,
refer to "2.1 Setting of service personnel maintenance mode."
2 Press System environment setup on the second page of the maintenance
menu.
The system environment setup screen is then displayed.
System env. setup
Ink type
Cable length
Nozzle diameter
Ink temperature correction
Excitation freq.
Excitation curve
*)
Ambient temp. upper lim.
Ambient temp. lower lim.
Excitation V-ref. (Max)
3 Modify the setting values.
*) Note: This item is automatically reset to the initial value when ink type is changed.
4 When setup is complete, press Back.
The screen returns to the maintenance menu.
[Note]
When change the ink type, Ink concentration control switch to enable on circulation environment
screen.
Set disable when does not use the Ink concentration control function on circulation environment
screen.
[Stop
-
(JP-K69
002
+
4
(m)
65
( m)
disable
+
-
(kHz; standard value: 68.9)
68.9
01
(standard value: 0)
( ; 40-50; standard value:45)
45
00
( ; 0- 5; standard value: 0)
19
(19-27)
2-4
Cable length
Ink temperature correction
Excitation curve
Ambient temperature lower limit
]
Com=0
)
enable
2015.07.07 12:45
Back
Back