2.3.2 Charging voltage confirmation

Voltage for confirmation of charging voltage is output for 3 minutes.
Be sure to perform this confirmation when performing the board exchange (EZJ126 and 125).
●This confirmation is performed in a state the IJ printer "stop" state.
1 Press Adjustment/operational checkout on the maintenance menu.
If Adjustment/operational checkout is not displayed on the maintenance menu, set the
service personnel maintenance mode on the login user selection screen.
For information on changing to the service personnel maintenance mode,
refer to "2.1 Setting of service personnel maintenance mode."
The adjustment/operational checkout menu is then displayed.
Adjust./oper. checkout
Excitation
adjustment
Auto-phase gain
adjustment
2 Press Charge voltage confirmation.
The Charge voltage confirmation screen is then displayed.
The voltage for confirmation is output for 3 minutes
Adjust./oper. checkout
<Charge voltage confirmation>
Execution takes 3 minutes.
[Stop
]
Charge voltage
Phase margin test
confirmation
Level sensor
Heating unit
confirmation
confirmation
Charge voltage confirmation
[Stop
]
Proc. status: In progress