2.20 Logging data

- Log the operating conditions to investigate the fault and warning condition.
- Log files are copied to the below holder when backup function is performed in the Service
personnel maintenance mode.
No.
File name
1
ALARM.TXT
2
AUTOSPLY.TXT
3
INKVISCO.TXT
4
SEQUENCE.TXT
- Up to 480 logging data can be recorded. If the number of logging data exceeds 480, the oldest
data is erased.
1 Contents of each log file
The following examples show the image of the logging data (text file) is pasted to Microsoft Excel
format.
(1) Fault and warning log (ALARM.TXT)
Date
Time
1
2011/7/7
7:05:29
2
2011/7/7
7:06:56
3
2011/7/7
8:06:56
4
2011/7/7
9:07:45
5
2011/7/7
10:12:04
6
2011/7/7
11:37:20
7
2011/7/7
12:07:22
8
2011/7/7
12:14:45
- Code: Log management code of each Fault and Warning.
(Refer to the 2.13 Fault / Warning log management code)
- Info1 to 4: Internal management code to specify the cause of alarm
List of Log files
Contents
Fault and warning log
Ink
and
replenishment data
Viscosity control
Circulation system control
[Example]
Code
Message
22 Internal Communication Error S
176 Viscometer not Calibrated
88 Battery Low
17 Heating Unit Sensor Fault
1 Ink Low Fault
2 Main Ink Tank Too Full
50 Cover Open
209 Storage Media Error
2-51
Logging timing
When Fault or Warning happens.
makeup
When
ink
replenished automatically.
(Each 30 min.)
When
ink
replenished automatically.
(Each 30 min.)
When
circulation
sequence is done.
Info1
Info2
0x0004
0x0000
0x0000
0x0000
0x0000
0x0000
0x0002
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
and
makeup
are
and
makeup
are
system
control
Info3
Info4
0
0
0
0
0
0
32
12
0
0
0
0
0
0
0
0

Hide quick links: