(2) How to insert the FFC
Insert the FFC with its contact surface facing down. Also insert the FFC in a direction
perpendicular to the connector. (Figure 3)
Figure 3
Insert the FFC in a direction perpendicular to the connector. Incorrect insertion like
shown in figure 4 could cause conduction failure or breakage of the actuator.
(3) How to lock the actuator
To lock the actuator, press it downward. When locking the actuator, apply the
pressure to the direction indicated by arrow (to the direction of inner side of the
connector) to avoid the separation of rotary shaft from the actuator.
]
[LCD external view
Maintenance door
[LCD replacement procedure
(1) Turn off the power and open the maintenance door.
(2) Remove flexible flat cable from LCD and EZJ128 board.
(3) Uninstall EZJ128 board.
(4) Remove attachment for the board.
(5) Remove LCD by unscrewing LCD fixing screws in 4 locations.
(6) After replacing, install the LCD by performing opposite procedure.
Contact surface
Caution when inserting FFC
!
Attachment
]
3-10
Figure 4
flexible flat cable
[RX2-S,B]
LCD